Biocompatibility & Toxicology

Applicable Standards

  • ISO 10993
  • ISO 18562
  • USP 66.1
  • USP 66.2
  • USP 1661
  • USP 1663
  • US FDA Guidance Document on ISO 10993-1 (Sep 2016)
  • MDR Regulation (EU) 2017/745 of the European Parliament and the Council of 05 April 2017 on Medical Devices

The days of the “check box” approach to biocompatibility are over.

Instead manufacturers of modern-day, complex devices need to assess the biocompatibility of their drug container and combination device materials and processes by taking a holistic risk-based approach to their biological safety evaluations.

Our experts have broken out the biological safety evaluation process into three distinct phases that can be used to accommodate a drug container or combination device in any stage of the product life-cycle.

This process is comprehensive and available today:

Biological Evaluation Plan (BEP)

A Biological Evaluation Plan (BEP) is an initial risk assessment offered by Nelson Labs is intended to meet the objectives outline in ISO 10993-1, clause 4 “General principles applying to biological evaluation of medical devices.” The first part of this clause states specifically that “The biological evaluation shall be planned, carried out, and documented by knowledgeable and experienced professionals.” The BEP takes into consideration the materials, processing, and historical use of the drug container or combination device. The deliverable is a signed biological evaluation plan recommending testing and information needed to demonstrate device safety.

 

Testing

Carry out the testing outlined in the BEP. This testing can include chemistry testing, biocompatibility testing, and/or written risk assessments.

 

Biological Evaluation Report (BER)

The Biological Evaluation Report (BER) is designed to meet the requirements outline in ISO 10993-1:2018, clause 7: “Expert assessors who have the necessary knowledge and experience shall determine and document:

  • the strategy and planned content for the biological evaluation of the medical device;
  • the criteria for determining the acceptability of the material for the intended purpose, in line with the risk management plan;
  • the adequacy of the material characterization;
  • the rationale for selection and/or waiving of tests;
  • the interpretation of existing data and results of testing;
  • the need for any additional data to complete the biological evaluation;
  • overall biological safety conclusions for the medical device.”

Services Summary

Nelson Labs offers a full trifecta of services to meet the requirements of ISO 10993 for Extractables & Leachables, Biocompatibility and Toxicological Assessments of drug containers and combination devices. Biocompatibility testing is very common in the drug container and combination device industry. However, with 24 possible categories, each with a unique set of testing requirements, the biocompatibility testing experience can be intimidating. Even after a drug container or combination device has been categorized, a myriad of decisions for each test remains.

Our Technical Consulting group can provide a full service experience. If you are familiar with ISO 10993 and its requirements, you may also select services you need below.

If you have additional questions about Biocompatibility & Toxicology testing, or would like to consult with the experts at Nelson Labs, just send us a request or call us at +1 (801) 290-7500.